PORTABLE CHILLER


25 Ton : Specifications : Features : Options

Get an Immediate Online Price Quote for this Air-Cooled Central Chiller now
Maximum Portable Chiller Water-Cooled Look CloserFeatures

STANDARD FEATURES (1)

FRAME CONSTRUCTION:
• Powder coated steel upright frame
• Galvanized steel cross frame
• Powder coated steel lift-off cabinetry
• Lift-off top panel
• Thermoformed ABS front fascia
• Small footprint - compact physical
  size
• Castors - for portability

REFRIGERANT CIRCUIT:
• Scroll compressor
• Shell & Tube water-cooled
  condenser with regulator valve
  and removable heads for
  servicing
• Refrigerant sight glass with
   moisture indicator
• Capacity control (by hot gas
  bypass valve)
• Liquid line solenoid valve
• Thermostatic expansion valve
• Brazed plate evaporator
• Full component insulation

COOLANT CIRCUIT:
• Stainless steel centrifugal pump
• Large capacity insulated non-ferrous
  reservoir (tank lid is standard on this model)
• Reservoir level sight glass
• Standard NPT process fittings

PRESSURE GAUGES:
• Refrigerant high pressure
• Refrigerant low pressure
• Coolant pressure

ELECTRICAL:
• Process pump motor starter
• Compressor motor contactor
• Fused transformer
• Power entry terminal block

SYSTEM LIMIT DEVICES:
• High pressure limit
• Low pressure limit
• Process pump motor overload
• Internal compressor overload
• Control circuit fuse

WARRANTIES:
• 1 year covering parts and labor
   Warranty Statement For DownloadWarranty Statement

Features

INSTRUMENT

Chiller Control Instrument For 2 - 30 Ton Maximu Series Portable Chillers Look Closer

M1 Series (standard instrument)
• Continuous To Process temperature display
• Selectable Setpoint temperature display
• Illuminated ON/OFF power switch
• Soft touch Setpoint selection keys
• Bright and easy-to-read LED Temperature
  display window
• Machine Status with Compressor and
  Capacity Control indicating lights
• Basic Machine Diagnostics with Refrigeration
  Fault indicating light

Features

OPTIONS

CHILLER CONTROL INSTRUMENT : LE Series
LE Instrument for Maximum Portable Process Liquid Chillers
• Continuous To Process and Setpoint
   temperature display
• Selectable From Process temperature display
• Temperature display in Fahrenheit or Celsius
• Status indicators for Power On, Compressor,
   Bypass/Unload, Alarm, Reservoir Level,
   Freezestat, Refrigerant circuit, and Low Flow
• Soft key operators
• RS-485 SPI communications port

REFRIGERANT CIRCUIT:
• Compressor CPR valve (for setpoints above 65°F)

COOLANT CIRCUIT:
• Overhead piping kit : factory or field installed
• No reservoir tank for gravity return applications
• Low flow bypass valve : manual or automatic
• Process line shut-off valves
• Larger process pumps

SYSTEM SAFETY DEVICES:
• Audible alarm
• Visual / audible alarm beacon

WARRANTIES:
• Extended compressor warranty

ELECTRICAL:
• Branch circuit fusing

SPECIFICATIONS (1)
Model: M1-25W (6)
(2) CAPACITY
Tons:
26
KW:
91.2
COMPRESSOR
HP:
13 @ 2
Type:
Scroll
PROCESS PUMP
HP:
5
GPM:
60
PSI:
59
Type:
Centrifugal
Construction:
Stainless Steel
CONNECTION SIZES
To:
2"
From:
2"
Water Make-Up:
1/2"
WATER-COOLED CONDENSER
(3) City:
32 gpm
(4) Tower:
63 gpm
(4) FULL LOAD AMPERAGE
230/3/60:
116
460/3/60:
58
575/3/60:
46
TANK CAPACITY
Holding:
65 gallons
Lid:
Standard
Auto Make-Up:
Standard
DIMENSIONS
Height:
57"
Width
34"
Depth:
80"
(5) WEIGHT
Shipping:
2,100 pounds

Notes:
1. Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liabililty. Selection of certain optional features may change listed specifications.
2. Tons capacity at 12,000 BTU/ton per hour @ 50°F LWT, 85°F condensing water and 105°F condensing temperature. Capacities may be +/- 5% as reserved by the compressor manufacturer. Operating at temperatures below 50° will reduce chiller capacity. The minimum recommended operating temperature when no glycol is used is 48°F.
3. City water requirements based on 60°F water supply at 20 PSI differential with a clean condenser. Tower water requirements based on 85°F water supply at 20 PSI differential with a clean condenser.
4. Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring.
5. Unit weight crated for shipment.
6. See Warranty Statement #W-700 for details.

Advantage Products
4 Steps to Complete Portable Chiller Information
Return to Step 1 : Select Condenser Style
Return to Step 2 : Select Unit Capacity
Step 3 : View Unit Details
Step 4 : Get Pricing Now

Supporting Documents
Maximum Series Literature Literature
PDFPDF
Color
6 Pages
180 KB
Manual Manual
PDFPDF
Color, 70 pages
613 KB


Knowledge Base Knowledge Base
PDF HTMLPDF & HTML
Documents covering the selection, service & operation of portable liquid chillers.
American Flag Advantage Engineering, Inc. 525 East Stop 18 Road, Greenwood, IN 46142   Phone: 317-887-0729   Fax: 317-881-1277
Privacy Statement and Terms of Use.    Sitemap   Product innovation and improvement is our constant goal. All features, specifications and pricing are subject to change without notice or liability. Products are assembled in the United States of America.
©1998 - 2010 ADVANTAGE ENGINEERING, INC