STANDARD FEATURES (1)
FRAME CONSTRUCTION:
• Powder coated steel upright frame
• Galvanized steel cross frame
• Powder coated steel lift-off cabinetry
• Lift-off top panel
• Thermoformed ABS front fascia
• Small footprint - compact physical
size
• Castors - for portability
REFRIGERANT CIRCUIT:
• Scroll compressor
• Shell & Tube water-cooled
condenser with regulator valve
and removable heads for
servicing
• Refrigerant sight glass with
moisture indicator
• Capacity control (by hot gas
bypass valve)
• Liquid line solenoid valve
• Thermostatic expansion valve
• Brazed plate evaporator
• Full component insulation
COOLANT CIRCUIT:
• Stainless steel centrifugal pump
• Large capacity insulated non-ferrous
reservoir (tank lid is standard on this model)
• Reservoir level sight glass
• Standard NPT process fittings
PRESSURE GAUGES:
• Refrigerant high pressure
• Refrigerant low pressure
• Coolant pressure
ELECTRICAL:
• Process pump motor starter
• Compressor motor contactor
• Fused transformer
• Power entry terminal block
SYSTEM LIMIT DEVICES:
• High pressure limit
• Low pressure limit
• Process pump motor overload
• Internal compressor overload
• Control circuit fuse
WARRANTIES:
• 1 year covering parts and labor
Warranty Statement
INSTRUMENT
M1 Series (standard instrument)
• Continuous To Process temperature display
• Selectable Setpoint temperature display
• Illuminated ON/OFF power switch
• Soft touch Setpoint selection keys
• Bright and easy-to-read LED Temperature
display window
• Machine Status with Compressor and
Capacity Control indicating lights
• Basic Machine Diagnostics with Refrigeration
Fault indicating light
OPTIONS
CHILLER CONTROL INSTRUMENT : LE Series

• Continuous To Process and Setpoint
temperature display
• Selectable From Process temperature display
• Temperature display in Fahrenheit or Celsius
• Status indicators for Power On, Compressor,
Bypass/Unload, Alarm, Reservoir Level,
Freezestat, Refrigerant circuit, and Low Flow
• Soft key operators
• RS-485 SPI communications port
REFRIGERANT CIRCUIT:
• Compressor CPR valve (for setpoints above 65°F)
COOLANT CIRCUIT:
• Overhead piping kit : factory or field installed
• No reservoir tank for gravity return applications
• Low flow bypass valve : manual or automatic
• Process line shut-off valves
• Larger process pumps
SYSTEM SAFETY DEVICES:
• Audible alarm
• Visual / audible alarm beacon
WARRANTIES:
• Extended compressor warranty
ELECTRICAL:
• Branch circuit fusing
Notes:
1. Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liabililty.
Selection of certain optional features may change listed specifications.
2. Tons capacity at 12,000 BTU/ton per hour @ 50°F LWT, 85°F condensing water and 105°F condensing temperature. Capacities may be +/- 5% as reserved by the compressor
manufacturer. Operating at temperatures below 50° will reduce chiller capacity. The minimum recommended
operating temperature when no glycol is used is 48°F.
3. City water requirements based on 60°F water supply at 20 PSI differential with a clean condenser. Tower water requirements based on 85°F
water supply at 20 PSI differential with a clean condenser.
4. Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring.
5. Unit weight crated for shipment.
6. See Warranty Statement #W-700 for details.

