Click Here For An Animated Schematic
INDOOR UNIT
This portable liquid chiller is designed to be placed and operated inside the production facility.
STANDARD FEATURES (1)
FRAME CONSTRUCTION:
• Stainless steel sheet metal
• Lift-off side panels
• Compact physical size
• Castors - for portability
REFRIGERANT CIRCUIT:
• Hermetic compressor
• Air-cooled condenser with finned tubes
• Propeller fan(s) induced air flow
• Refrigerant sight glass with moisture
indicator
• Filter-drier
• Liquid line solenoid valve
• Thermostatic expansion valve
• Brazed plate evaporator
COOLANT CIRCUIT:
• High Flow Centrifugal pump
• Large capacity insulated non-ferrous
reservoir (tank lid optional this model)
• Reservoir level sight glass
• Standard NPT process fittings
PRESSURE GAUGES:
• Refrigerant high pressure
• Refrigerant low pressure
• Coolant pressure
ELECTRICAL:
• Process pump motor starter
• Compressor motor contactor
• Fused transformer
• Power entry terminal block
SYSTEM LIMIT DEVICES:
• High pressure limit
• Low pressure limit
• Process pump motor overload
• Internal compressor overload
• Control circuit fuse
WARRANTY:
• 1 year covering parts and labor
Warranty Statement
INSTRUMENT
M1 Series (standard instrument)
• Continuous To Process temperature display
• Selectable Setpoint temperature display
• Illuminated ON/OFF power switch
• Soft touch Setpoint selection keys
• Bright and easy-to-read LED Temperature display window
• Machine Status with Compressor and Capacity Control indicating lights
• Basic Machine Diagnostics with Refrigeration Fault indicating light
OPTIONS
REFRIGERANT CIRCUIT:
• Compressor CPR valve (for setpoints above 65°F)
COOLANT CIRCUIT:
• Overhead piping kit : factory or field installed
• No reservoir tank for gravity return applications
• Process line shut-off valves
• Larger process pumps
• Tank Lid
• Low flow bypass valve
SYSTEM SAFETY DEVICES:
• Audible alarm
• Visual / audible alarm beacon
WARRANTIES:
• Extended compressor warranty
ELECTRICAL:
• Branch circuit fusing
Specification Notes:
1. Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liabililty.
Selection of certain optional features may change listed specifications.
2. Tons capacity at 12,000 BTU/ton per hour @ 50°F LWT @ 115°F condensing temperature. Capacities may be +/- 5% as reserved by the compressor
manufacturer. Operating at temperatures below 50° will reduce chiller capacity. The minimum recommended
operating temperature when no glycol is used is 48°F.
3. Design ambient conditions. Loss of capacity and/or difficulty operating will occur at higher ambients. Minimum recommended ambient is 60°F.
4. Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring.
5. Approximate unit weight crated for shipment.
6. See Warranty Statement #W-700 for details.