PORTABLE CHILLER


30 Tons : Specifications : Features : Options

Get an Immediate Online Price Quote for this Air-Cooled Central Chiller now
Maximum Portable Chiller 15 - 30 Tons with Centrifugal Blower
Look Closer at the Advantage 15 - 30 ton portable liquid chiller
Typical Unit Appearance Shown.

Click Here For An Animated Schematic

INDOOR UNIT
This portable liquid chiller is designed to be placed and operated inside the production facility.

Features

STANDARD FEATURES (1)

FRAME CONSTRUCTION:
• Powder coated steel upright frame
• Galvanized steel cross frame
• Powder coated steel cabinetry
• Lift-off side panels
• Castors - for portability

REFRIGERANT CIRCUIT:
• Scroll compressor
• Air-cooled condenser with finned tubes
• Centrifugal Blower induced air flow
• Refrigerant sight glass with moisture
   indicator
• Filter-drier
• Liquid line solenoid valve
• Thermostatic expansion valve
• Brazed plate evaporator

COOLANT CIRCUIT:
• High Flow Centrifugal pump
• Large capacity insulated non-ferrous
   reservoir (tank lid is standard on this model)
• Reservoir level sight glass
• Automatic water make-up system
• Standard NPT process fittings

PRESSURE GAUGES:
• Refrigerant high pressure
• Refrigerant low pressure
• Coolant pressure

ELECTRICAL:
• Process pump motor starter
• Compressor motor contactor
• Fused transformer
• Power entry terminal block

SYSTEM LIMIT DEVICES:
• High pressure limit
• Low pressure limit
• Process pump motor overload
• Internal compressor overload
• Control circuit fuse

WARRANTY:
• 1 year covering parts and labor
   Warranty Statement For DownloadWarranty Statement

Features

INSTRUMENT

Chiller Control Instrument For 2 - 30 Ton Maximum Series Portable Chillers Look Closer

M1 Series (standard instrument)
• Continuous To Process temperature display
• Selectable Setpoint temperature display
• Illuminated ON/OFF power switch
• Soft touch Setpoint selection keys
• Bright and easy-to-read LED Temperature display window
• Machine Status with Compressor and Capacity Control indicating lights
• Basic Machine Diagnostics with Refrigeration Fault indicating light

Features

OPTIONS

CHILLER CONTROL INSTRUMENT : LE Series
LE Instrument for Maximum Portable Process Liquid Chillers
• Continuous To Process and Setpoint temperature display
• Selectable From Process temperature display
• Temperature display in Fahrenheit or Celsius
• Status indicators for Power On, Compressor, Bypass/Unload,
  Alarm, Reservoir Level, Freezestat, Refrigerant circuit, and Low Flow
• Soft key operators
• RS-485 SPI communications port

REFRIGERANT CIRCUIT:
• Compressor CPR valve (for setpoints above 65°F)

COOLANT CIRCUIT:
• Overhead piping kit : factory or field installed
• No reservoir tank for gravity return applications
• Process line shut-off valves
• Larger process pumps
• Low flow bypass valve

SYSTEM SAFETY DEVICES:
• Audible alarm
• Visual / audible alarm beacon

WARRANTIES:
• Extended compressor warranty

ELECTRICAL:
• Branch circuit fusing

SPECIFICATIONS (1)
Model: M1-30A (6)
(2) CAPACITY
Tons:
29
KW:
101.8
COMPRESSOR
HP:
15 x 2
Type:
Scroll
PROCESS PUMP
HP:
5
GPM:
72
PSI:
57
Type:
Centrifugal
Construction:
Stainless Steel
CONNECTION SIZES
To:
2"
From:
2"
Make-Up:
1/2"
AIR-COOLED CONDENSER
Type:
Blower
CFM:
30,000
(3) Ambient:
95°
(7) SP:
1.35
(4) FULL LOAD AMPERAGE
230/3/60:
178
460/3/60:
89
575/3/60:
72
TANK CAPACITY
Holding:
65 gallons
Lid:
Standard
Auto Make-Up:
Standard
DIMENSIONS
Height:
96"
Width
58"
Depth:
70"
(5) WEIGHT
Shipping:
3,500 pounds

Specification Notes:
1. Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liabililty. Selection of certain optional features may change listed specifications.
2. Tons capacity at 12,000 BTU/ton per hour @ 50°F LWT @ 115°F condensing temperature. Capacities may be +/- 5% as reserved by the compressor manufacturer. Operating at temperatures below 50° will reduce chiller capacity. The minimum recommended operating temperature when no glycol is used is 48°F.
3. Design ambient conditions. Loss of capacity and/or difficulty operating will occur at higher ambients. Minimum recommended ambient is 60°F.
4. Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring.
5. Approximate unit weight crated for shipment.
6. See Warranty Statement #W-700 for details.
7. Static pressure in inches of water.

Advantage Products
4 Steps to Complete Portable Chiller Information
Return to Step 1 : Select Condenser Style
Return to Step 2 : Select Unit Capacity
Step 3 : View Unit Details
Step 4 : Get Pricing Now

Supporting Documents
Maximum Series Literature Literature
PDFPDF
Color
6 Pages
180 KB
Manual Manual
PDFPDF
Color, 70 pages
613 KB


Knowledge Base Knowledge Base
PDF HTMLPDF & HTML
Documents covering the selection, service & operation of portable liquid chillers.
American Flag Advantage Engineering, Inc. 525 East Stop 18 Road, Greenwood, IN 46142   Phone: 317-887-0729   Fax: 317-881-1277
Privacy Statement and Terms of Use.    Sitemap   Product innovation and improvement is our constant goal. All features, specifications and pricing are subject to change without notice or liability. Products are assembled in the United States of America.
©1998 - 2010 ADVANTAGE ENGINEERING, INC